0.6/1kv Aluminum cable Insulated ABC Cable JkLYJ 4x10mm
Applications
Primarily used for overhead service application such as street lighting,outdoor lighting,and temporary service for construction, To be used at voltage of 600V to 2200V phase-to-phase or less at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross liked polyethylene insulated conductors.
Standards
We could produce the cable according to many standards: ICEA S-76-474,
ICEA S-95-658,ICEA S-61-402,ICEA S-66-524.NFC 33. IEC
we will do our best to meet your requirements
Specification
SPEC mm2 |
Conductor structure | Insulation Material |
Insulation Thickness (mm) |
Approx overall diameter (mm) |
Approx weight (kg/km) |
|
Phase (compacted Al) | Neutral (alloy) |
|||||
No./mm | No./mm | |||||
1*16+1*16 | 7/1.72 | 7/1.72 | XLPE (HDPE) |
1.2 | 12.5 | 110.1 |
1*25+1*25 | 7/2.15 | 7/2.15 | 1.2 | 14.9 | 163.9 | |
1*35+1*35 | 7/2.54 | 7/2.54 | 1.4 | 17.5 | 229.0 | |
1*50+1*50 | 7/2.92 | 7/2.92 | 1.4 | 20.1 | 300.0 | |
1*70+1*70 | 19/2.15 | 19/2.15 | 1.4 | 23.6 | 423.2 | |
1*95+1*95 | 19/2.54 | 19/2.54 | 1.6 | 27.6 | 585.4 | |
2*16+1*16 | 7/1.72 | 7/1.72 | 1.2 | 14.2 | 175.8 | |
2*25+1*25 | 7/2.15 | 7/2.15 | 1.2 | 16.7 | 258.4 | |
2*35+1*35 | 7/2.54 | 7/2.54 | 1.4 | 19.7 | 361.2 | |
2*50+1*50 | 7/2.92 | 7/2.92 | 1.4 | 22.5 | 472.1 | |
2*70+1*70 | 19/2.15 | 19/2.15 | 1.4 | 26.1 | 658.3 | |
2*95+1*95 | 19/2.54 | 19/2.54 | 1.6 | 30.5 | 908.2 | |
3*16+1*16 | 7/1.72 | 7/1.72 | 1.2 | 16.3 | 241.5 | |
3*25+1*25 | 7/2.15 | 7/2.15 | 1.2 | 19.1 | 353.6 | |
3*35+1*35 | 7/2.54 | 7/2.54 | 1.4 | 22.5 | 493.5 | |
3*50+1*50 | 7/2.92 | 7/2.92 | 1.4 | 25.7 | 644.1 | |
3*70+1*70 | 19/2.15 | 19/2.15 | 1.4 | 29.7 | 895.2 | |
3*95+1*95 | 19/2.54 | 19/2.54 | 1.6 | 34.6 | 1233.5 |
Nominal Cross Section | Minimum Breaking Load | current Rating in Air | Nominal Over all Diameter | Total Weight | Outer Diameter |
mm2 | Kn | A | mm | kg/km | mm |
2×16RM | 1.910 | 2.5 | 72 | 147 | 15.6 |
2×25RM | 1.200 | 4.0 | 107 | 208 | 18 |
2×35RM | 0.868 | 5.5 | 132 | 277 | 20 |
2×50RM | 0.641 | 8.0 | 165 | 361 | 23.5 |
4×16RM | 1.910 | 2.5 | 72 | 286 | 18.8 |
4×25RM | 1.200 | 4.0 | 107 | 430 | 21.2 |
4×35RM | 0.868 | 5.5 | 132 | 553 | 24.1 |
4×50RM | 0.641 | 8.0 | 165 | 746 | 27.8 |
4×70RM | 0.443 | 10.7 | 205 | 1.009 | 31.8 |
4×95RM | 0.320 | 13.7 | 240 | 1.332 | 37.8 |
4×120RM | 0.253 | 18.6 | 290 | 1.632 | 54.4 |
4×35+1×35RM | 0.868/0.868 | 5.5/5.5 | 132/132 | 694 | 30 |
4×50+1×25RM | 0.641/1.200 | 8.0/4.0 | 165/107 | 814 | 31.9 |
4×50+1×35RM | 0.641/0.868 | 8.5/5.5 | 165/132 | 845 | 31.9 |
4×70+1×25RM | 0.443/1.200 | 10.7/4.0 | 205/107 | 1.105 | 36 |
4×70+2×25RM | 0.443/1.200 | 10.7/4.0 | 205/107 | 1.217 | 40 |
4×70+1×35RM | 0.443/0.868 | 10.7/5.5 | 205/132 | 1.15 | 36.2 |