Customization: | Available |
---|---|
Type: | Mining Cable |
Conductor Type: | Stranded |
Still deciding? Get samples of US$ 0.01/Meter
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type MP-GC cable is suitable for use in medium voltage distribution circuits for permanent installations in bore holes, shafts, open pits, strip mines and tunnels.
Features:
Nominal voltage:5kV/8kV/15kV.
Flexible rope stranded, tin-coated copper conductor
Extruded semi-conducting compound conductor shield, cross-linked polyethylene(XLPE) insulation, extruded semi-conducting compound insulation shield,Copper tape shield.
Identification of power conductors are black, white and red. The ground check conductor is yllow. The grounding conductor is bare annealed copper.
Three insulated conductors, two ground wires and a ground check are cabled together.
Black PVC sheath.
Max permissible continuous operating temperature of conductor shall not exceed 90°C.
Meets or exceeds industry requirements of ASTM B3, ASTM B33, ICEA S-75-381 or other standards required by customers.
Construction: The tinned copper conductor is covered by an extruded semi-conducting compound. Insulation is cross-linked polyethylene(XLPE) with an extruded semi- conducting compound. There is a copper tape over each conductor as metal shield. Identification of power conductors are black, white and red. The ground check conductor is yllow. The grounding conductor is bare annealed copper. Three shielded conductors are assembled round in a helical configuration with two uninsulated ground wires, one yellow insulated ground check. and sheathed with black PVC.
Application : Type MP-GC cable is suitable for use in medium voltage distribution circuits for permanent installations in bore holes, shafts, open pits, strip mines and tunnels.
Rated Voltage: 5kV/8kV/15kV
Operating Temperature: Max permissible continuous operating temperature of conductor shall not exceed 90°C.
Bending Radius: 12D, D = Actual outer diameter of cable (mm)
Standard:ASTM B3, ASTM B33, ICEA S-75-381 or other standards required by customers.
5KV XLPE Insulated Mining Cable, Type MP-GC
Power conductor | Grounding Conductor | Ground Check Conductor | Sheath Thickness | Approx. Overall Diameter | |||||
Conductor Size | Insulation Thickness | Conductor Size | Conductor Size | Insulation Thickness | |||||
AWG/ MCM |
mm² | In. | AWG/ MCM |
mm² | AWG/ MCM |
mm² | In. | In. | In. |
4 2 |
21.2 33.6 |
0.090 0.090 |
8 6 |
8.37 13.3 |
8 8 |
8.37 8.37 |
0.045 0.045 |
0.110 0.110 |
1.425 1.567 |
1 | 42.4 | 0.090 | 5 | 16.8 | 8 | 8.37 | 0.045 | 0.110 | 1.654 |
1/0 2/0 |
53.5 67.4 |
0.090 0.090 |
4 3 |
21.2 26.7 |
8 8 |
8.37 8.37 |
0.045 0.045 |
0.110 0.110 |
1.760 1.878 |
4/0 | 107.2 | 0.090 | 1 | 42.4 | 8 | 8.37 | 0.045 | 0.140 | 2.161 |
250 350 |
127 177 |
0.090 0.090 |
1/0 2/0 |
53.5 67.4 |
8 8 |
8.37 8.37 |
0.045 0.045 |
0.140 0.140 |
2.299 2.539 |
500 | 253 | 0.090 | 4/0 | 107.0 | 8 | 8.37 | 0.045 | 0.140 | 2.850 |
Power conductor | Grounding Conductor | Ground Check Conductor | Sheath Thickness |
Approx. Overall Diameter | ||||||||||||||||
Conductor Size | Insulation Thickness | Conductor Size | Conductor Size | Insulation Thickness | ||||||||||||||||
AWG/ MCM | mm² | In. | AWG/ MCM | mm² | AWG/ MCM | mm² | In. | In. | In. | |||||||||||
4 2 |
21.2 33.6 |
0.115 0.115 |
8 6 |
8.37 13.3 |
8 8 |
8.37 8.37 |
0.045 0.045 |
0.110 0.110 |
1.543 1.673 |
|||||||||||
1 | 42.4 | 0.115 | 5 | 16.8 | 8 | 8.37 | 0.045 | 0.110 | 1.783 | |||||||||||
1/0 2/0 |
53.5 67.4 |
0.115 0.115 |
4 3 |
21.2 26.7 |
8 8 |
8.37 8.37 |
0.045 0.045 |
0.140 0.140 |
1.890 2.031 |
|||||||||||
4/0 | 107.2 | 0.115 | 1 | 42.4 | 8 | 8.37 | 0.045 | 0.140 | 2.291 | |||||||||||
250 350 |
127 177 |
0.115 0.115 |
1/0 2/0 |
53.5 67.4 |
8 8 |
8.37 8.37 |
0.045 0.045 |
0.140 0.140 |
2.429 2.657 |
|||||||||||
500 | 253 | 0.115 | 4/0 | 107.0 | 8 | 8.37 | 0.045 | 0.140 | 2.969 | |||||||||||
Power conductor | Grounding Conductor | Ground Check Conductor | Sheath Thickness | Approx. Overall Diameter | ||||||||||||||||
Conductor Size | Insulation Thickness | Conductor Size | Conductor Size | Insulation Thickness | ||||||||||||||||
AWG/ MCM |
mm² | In. | AWG/ MCM |
mm² | AWG/ MCM |
mm² | In. | In. | In. | |||||||||||
2 | 33.6 | 0.175 | 6 | 13.3 | 8 | 8.37 | 0.045 | 0.140 | 2.031 | |||||||||||
1 | 42.4 | 0.175 | 5 | 16.8 | 8 | 8.37 | 0.045 | 0.140 | 2.138 | |||||||||||
1/0 2/0 |
53.5 67.4 |
0.175 0.175 |
4 3 |
21.2 26.7 |
8 8 |
8.37 8.37 |
0.045 0.045 |
0.140 0.140 |
2.213 2.323 |
|||||||||||
4/0 | 107.2 | 0.175 | 1 | 42.4 | 8 | 8.37 | 0.045 | 0.140 | 2.591 | |||||||||||
250 350 |
127 177 |
0.175 0.175 |
1/0 2/0 |
53.5 67.4 |
8 8 |
8.37 8.37 |
0.045 0.045 |
0.140 0.140 |
2.701 2.969 |
|||||||||||
500 | 253 | 0.175 | 4/0 | 107.0 | 8 | 8.37 | 0.045 | 0.170 | 3.346 |
FAQ
1.Are you a manufacturer or trading company?
We are a professional manufacturer.We can control your order from the first
beginning to the last.
Welcome to visit us.We'll pick you up in Zhengzhou
2. How can I get a sample to test your quality?
The samples are free for you.New clients are expected to pay for the courier
cost.
3.What's your Minimum Order Quantity?
Normally 1000m.How ever the cable is very heavy.
You'd better order a suitable quantity to avoid the high freight.
Sea transportation is the best option.
4.Can I get a discount?
It depends on your quantity,We can make a discount and afford the freight.
Pls kindly contact us.
5. Does your company accept OEM production?
Yes, could print your company name we even custom the quality card to
promote your company.