high voltage bare conductor SCA 50 mm hda and 100 mm hda
Product Description
A,Specifications
a.High tensile strength
b.Long life
c.Light in weight
d.Suitable for high as well as extra high overhead voltage lines
B,Standard: ASTM B232 ,IEC61089, BS215 part2, DIN48204, BS EN50182, GB/T 1179-2008
C,Brief Description:
ACSR conductor consists of a solid or stranded steel core surrounded by strands of aluminium (E.C. GRADE).
ACSR Conductor may be manufactured for having a wide range of tensile strength as per requirement.
The principal advantage of these conductors are high tensile strength and light weight with longer spans as well as
with lesser supports. Due to the greater diameter of ACS Conductor a much higher corona limit can be obtained causing
big advantages on high as well as extra high voltage overhead lines.
D,Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable.
ACSR Conductor offers optimal strength for line design. Variable steel core stranding enables
desired strength to be achieved without sacrificing ampacity. ACSR Conductor are used extensively
for overhead ground wires, river crossings etc. These ACSR Conductor are available with us in various types for
meeting the exact requirements of the clients.
E,Package:In coils, wooden drums, steel drums or steel-wooden drums.
We could producing according to the customers' requirements.Welcome your request for any quotations!
BS ACSR conductor SCA conductor
Code Name |
Nominal Area |
Stranding &Wire Dia. |
Approximate Overall Dia. |
Section Area |
Approximate Weight |
Breaking Load |
DC Resistance at 20ºC |
Current Rating |
Aluminum |
Steel |
Aluminum |
Steel |
Total |
mm2
|
No. |
mm
|
No. |
mm
|
mm
|
mm2
|
mm2
|
mm2
|
Kg/km |
kN |
Ω/km |
A |
Gopher |
25 |
6 |
2.36 |
1 |
2.36 |
7.08 |
26.25 |
4.37 |
30.62 |
106 |
9.61 |
1.093 |
126 |
Weasel |
30 |
6 |
2.59 |
1 |
2.59 |
7.77 |
31.6 |
5.3 |
36.9 |
128.0 |
11.45 |
0.9077 |
134 |
Ferret |
40 |
6 |
3 |
1 |
3 |
9 |
42.4 |
7.1 |
49.5 |
171.7 |
15.20 |
0.6766 |
161 |
Rabbit |
50 |
6 |
3.35 |
1 |
3.35 |
10.05 |
52.9 |
8.8 |
61.7 |
214.1 |
18.35 |
0.5426 |
185 |
Horse |
70 |
12 |
2.79 |
7 |
2.79 |
13.95 |
73.4 |
42.8 |
116.2 |
538.1 |
61.20 |
0.3936 |
268 |
Dog |
100 |
6 |
4.72 |
7 |
1.57 |
14.15 |
105.0 |
13.6 |
118.5 |
394.7 |
32.70 |
0.2733 |
278 |
Wolf |
150 |
30 |
2.59 |
7 |
2.59 |
18.13 |
158.1 |
36.9 |
194.9 |
725.9 |
69.20 |
0.1828 |
355 |
Dingo |
150 |
18 |
3.35 |
1 |
3.35 |
16.75 |
158.7 |
8.8 |
167.5 |
507.4 |
35.70 |
0.1815 |
349 |
Lynx |
175 |
30 |
2.79 |
7 |
2.79 |
19.53 |
183.4 |
42.8 |
226.2 |
842.4 |
79.80 |
0.1576 |
386 |
Caracal |
175 |
18 |
3.61 |
1 |
3.61 |
18.05 |
184.2 |
10.2 |
194.5 |
589.2 |
41.10 |
0.1563 |
383 |
Panther |
200 |
30 |
3 |
7 |
3 |
21 |
212.1 |
49.5 |
261.5 |
974.0 |
92.25 |
0.1363 |
421 |
Jaguar |
200 |
18 |
3.86 |
1 |
3.86 |
19.3 |
210.6 |
11.7 |
222.3 |
673.6 |
46.55 |
0.1367 |
415 |
Zebra |
400 |
54 |
3.18 |
7 |
3.18 |
28.62 |
428.9 |
55.6 |
484.5 |
1621.3 |
131.90 |
0.06741 |
635 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HDA conductor
Technical Characteristics Based on Standard BS 215-1 |
Code name |
Nominal aluminium area |
Stranding and wire diameter |
Sectional area |
Approx. overall diameter |
Approx. mass |
Calculated D.C. resistance at 20oC |
Calculated breaking load |
mm2 |
No./mm |
mm2 |
mm |
kg/km |
Ω/km |
kN |
MIDGE |
22 |
7/2.06 |
23.33 |
6.18 |
64 |
1.227 |
3.99 |
ANT |
50 |
7/3.10 |
52.83 |
9.3 |
145 |
0.5419 |
8.28 |
FLY |
60 |
7/3.40 |
63.55 |
10.2 |
174 |
0.4505 |
9.9 |
WASP |
100 |
7/4.39 |
106 |
13.17 |
290 |
0.2702 |
16 |
HORNET |
150 |
19/3.25 |
157.6 |
16.25 |
434 |
0.1825 |
25.7 |
CHAFER |
200 |
19/3.78 |
213.2 |
18.9 |
587 |
0.1349 |
32.4 |
COCKROACH |
250 |
19/4.22 |
265.7 |
21.1 |
731 |
0.1083 |
40.4 |
BUTTERFLY |
300 |
19/4.65 |
322.7 |
23.25 |
888 |
0.08916 |
48.75 |
Packaging & Shipping
Certifications
Company Profile
After Sales Service